R&S®SMA100B RF and microwave signal generator, front low R&S®SMA100B RF and microwave signal generator, front low R&S®SMA100B RF and microwave signal generator, back low R&S®SMA100B RF and microwave signal generator, front low R&S®SMA100B RF and microwave signal generator, back low R&S®SMA100B RF and microwave signal generator, side view

Key Facts

  • Frequency range: 8 kHz to 3, 6, 12.75, 20, 31.8, 40, 50 and 67 GHz (overrange up to 72 GHz). Frequency extension from 50 GHz to 170 GHz with the R&S®SZM frequency multiplier
  • SSB phase noise of  –132 dBc (typ.) at 10 GHz and 10 kHz offset
  • Wideband noise of –162 dBc (meas.) at 10 GHz and 30 MHz offset
  • Maximum output power exceeds 30 dBm across wide frequency ranges
  • Exceptionally low harmonics

Performance leadership without compromise up to 67 GHz, with upconverter up to 170 GHz

The R&S®SMA100B RF and microwave signal generator delivers uncompromising maximum performance. It provides the purest output signals while maintaining the highest output power levels with the lowest harmonics, far outpacing the competition. As the world's leading signal generator, it can handle the most demanding module and system T&M tasks in the RF semiconductor, wireless communications, aerospace and defense industries.

Features & benefits

First-class devices thanks to first-class signals

The R&S®SMA100B delivers uncompromising maximum performance. 

  • It provides the purest output signals with the highest output power levels and the lowest harmonics.
  • Frequency range from 8 kHz up to 67 GHz (overrange 72 GHz)
  • Frequency extension from 50 GHz to 170 GHz with the R&S®SZM frequency multiplier
  • Lowest SSB phase noise of –132 dBc (typ.) at 10 GHz and 10 kHz offset
  • Virtually no wideband noise of –162 dBc (meas.) at 10 GHz and 30 MHz offset
  • Maximum output power exceeds 30 dBm across wide frequency ranges
  • Exceptionally low harmonics
  • State-of-the-art GUI with touch display

SSB phase noise for different frequencies
Ingrandisci immagine

SSB phase noise for different frequencies

Measured SSB phase noise performance of the R&S®SMA100B with the R&S®SMAB-B711(N) option

Very high uncompromising output power

Large dynamic range, excellent level accuracy and level repeatability 

Very high output power is often required in the microwave frequency range because the higher the frequency, the more attenuation. The R&S®SMA100B offers different output power stages to compensate for such losses. As a result, no downstream external amplifier is required. Exceptionally high output power levels (measured values)

  • Ultra high output power up to 38 dBm with the 6 GHz instrument
  • Over 30 dBm at 18 GHz and 28 dBm at 20 GHz with the 20 GHz instrument
  • Over 30 dBm between 20 GHz and 36 GHz with the 40 GHz instrument
  • Over 22 dBm between 40 GHz and 65 GHz with the 67 GHz instrument

 Maximum measured output power
Ingrandisci immagine

Maximum measured output power

Measured maximum available output power for the 50 GHz and the 67 GHz instrument (standard, high and ultra-high output power options)

User friendly in every detail

Easy integration into test systems and innovative operating features

  • Flexible 2 HU or 3 HU housing
  • 3 HU with large 7" display and multiple front panel connectors
  • Ergonomic GUI with touch display
  • Frequently used items can be added to user menus for quick and easy access to any necessary settings in one place
  • The R&S®SMA100B also has a SCPI macro recorder with a code generator to automatically record manual settings and create an executable MATLAB® script

Innovative operating features
Ingrandisci immagine

Innovative operating features

The built-in SCPI macro recorder and code generator supports fast, easy generation of SCPI program sequences

R&S®LegacyPro: refresh your technology

Trade in your legacy signal generators

R&S®LegacyPro enables the R&S®SMA100B to reliably emulate a wide range of legacy generators from vendors such as Keysight, Agilent, HP, Anritsu and Rohde & Schwarz. As a result, the R&S®SMA100B can be deployed in legacy systems without major software changes, effectively increasing uptime, lowering cost of ownership and lengthening the useful life of the test system.

R&S®LegacyPro
Ingrandisci immagine

R&S®LegacyPro

Enjoy plug and play replacement of your legacy signal generators with R&S®LegacyPro and the R&S®SMA100B;  

High-end ADC and DAC component testing

Measure the true performance of your device 

Analog input bandwidth and required clock frequency increase with each new ADC generation. The increase in the effective number of bits also results in a larger signal-to-noise ratio. This means that extremely clean, high-frequency signals exceeding the DUT performance are required to test ADCs and DACs. The outstanding R&S®SMA100B performance is perfect for optimizing DUTs and making improvements technically feasible in the first place.

The R&S®SMA100B in an ADC/DAC application
Ingrandisci immagine

The R&S®SMA100B in an ADC/DAC application

Compact ADC test setup for clock signals up to 6 GHz using a single R&S®SMA100B with an integrated second source

 R&S®NRP power sensor connectivity

An R&S®NRP power sensor can be connected to the R&S®SMA100B;

A DUT is rarely connected directly to the generator. Cables and other components are often between the generator and the DUT. This shifts the reference plane from the generator RF output to the DUT. An R&S®NRP power sensor can be connected to the R&S®SMB100B for extremely precise calibration (tenth of a dB) on the new reference plane.

 R&S®NRP power sensor connectivity
Ingrandisci immagine

R&S®NRP power sensor connectivity

R&S®SMA100B with connected Rohde &;Schwarz power sensor    

UCOR (user correction)

Compensation of an external frequency response

DUTs are often connected to the signal generator via long cables or other frequency dependent components, making it very important to compensate for frequency response. The R&S®SMA100B provides a user correction (UCOR) function for this purpose. Together with an R&S®NRP power sensor, the UCOR values are automatically determined at the push of a button. A frequency response compensated RF signal is available at the new reference plane for UCOR.

Setup and UCOR function
Ingrandisci immagine

Setup and UCOR function

Relative output power display when using cables and other components (with their own frequency response) between the R&S®SMA100B and a DUT.

Closed loop power control (CLPC)

Dynamic compensation of external frequency responses and drifts by the R&S®SMA100B with a connected R&S®NRP power sensor

The dynamic closed loop power control is a standard feature of the R&S®SMA100B. In combination with an R&S®NRP power sensor, the dynamic closed loop power ensures highly accurate and stable input power over time to the DUT regardless of unexpected signal chain losses or gains, unwanted power drifts in the setup or target level changes. The 1GP141 application note describes in great detail the closed loop power control function, the possible signals,suitable signal generator, R&S®NRP power sensors and what needs to be taken into account. Please read the application note before using the closed loop power control for the first time to avoid a possible damage to the DUT.

Uninterrupted level sweep with high dynamic range

When measuring gain transfer functions or output saturation points in amplifiers with an integrated automatic level control (ALC), the signal generator must provide a wide uninterrupted level sweep range. The R&S®SMA100B with the R&S®SMAB-K724  option provides the following:

  • Blank-free (uninterrupted) level sweep with exceptionally high dynamic range
  • High level linearity across the entire level sweep range

Ingrandisci immagine

Uninterrupted high dynamic range level sweep with the R&S®SMA100B;

Available options

Frequency options
Product
Descrizione
R&S®SMAB-B103

Order Number 1420.8488.02

Descrizione

8 kHz to 3 GHz

R&S®SMAB-B106

Order Number 1420.8588.02

Descrizione

8 kHz to 6 GHz

R&S®SMAB-B112

Order Number 1420.8688.02

Descrizione

8 kHz to 12.75 GHz

R&S®SMAB-B120

Order Number 1420.8788.02

Descrizione

8 kHz to 20 GHz

R&S®SMAB-B131

Order Number 1420.8888.02

Descrizione

8 kHz to 31.8 GHz

R&S®SMAB-B140

Order Number 1420.8988.02

Descrizione

8 kHz to 40 GHz

R&S®SMAB-B140N

Order Number 1420.8965.02

Descrizione

8 kHz to 40 GHz, limited minimum pulse width

R&S®SMAB-B150

Order Number 1420.9049.02

Descrizione

8 kHz to 50 GHz

R&S®SMAB-B150N

Order Number 1420.9026.02

Descrizione

8 kHz to 50 GHz, limited minimum pulse width

R&S®SMAB-B167

Order Number 1420.9149.02

Descrizione

8 kHz to 67 GHz

R&S®SMAB-B167N

Order Number 1420.9126.02

Descrizione

8 kHz to 67 GHz, limited minimum pulse width

R&S®SMAB-B29

Order Number 1420.8088.02

Descrizione

Differential clock synthesizer, 3 GHz

R&S®SMAB-K722

Order Number 1420.9810.02

Descrizione

Clock synthesizer frequency extension to 6 GHz

Phase noise performance options
Product
Descrizione
R&S®SMAB-B709

Order Number 1420.9849.02

Descrizione

Low Phase Noise for R&S®SMAB-B106/-B112/-B120/-B131/-B140(N)/-B150(N)/-B167(N)

R&S®SMAB-B710

Order Number 1420.8007.02

Descrizione

Improved Close-in Phase Noise for R&S®SMAB-B106/-B112/-B120/-B131/-B140/-B150/-B167

R&S®SMAB-B710N

Order Number 1420.8107.02

Descrizione

Improved Close-in Phase Noise for R&S®SMAB-B103

R&S®SMAB-B711

Order Number 1420.8020.02

Descrizione

Ultra Low Phase Noise for R&S®SMAB-B106/-B112/-B120/-B131/-B140/-B150/-B167

R&S®SMAB-B711N

Order Number 1420.8120.02

Descrizione

Ultra Low Phase Noise for R&S®SMAB-B103

Reference oscillator options
Product
Descrizione
R&S®SMAB-B1H

Order Number 1420.8188.02

Descrizione

High Performance OCXO Reference Oscillator

R&S®SMAB-K703

Order Number 1420.9761.02

Descrizione

100 MHz, 1 GHz Reference Input and Output

R&S®SMAB-K704

Order Number 1420.9778.02

Descrizione

Flexible Reference Input 1 MHz to 100 MHz

Output power options
Product
Descrizione
R&S®SMAB-K31

Order Number 1420.7100.02

Descrizione

High output power, 3 GHz/6 GHz

R&S®SMAB-B32

Order Number 1420.7200.02

Descrizione

Ultra high output power, 3 GHz/6 GHz

R&S®SMAB-K33

Order Number 1420.7300.02

Descrizione

High output power, 12.75 GHz/20 GHz

R&S®SMAB-B34

Order Number 1420.7400.02

Descrizione

Ultra high output power, 12.75 GHz/20 GHz

R&S®SMAB-B35

Order Number 1420.7500.02

Descrizione

High output power 31.8 GHz/40 GHz

R&S®SMAB-K36

Order Number 1420.9178.02

Descrizione

Ultra high output power 31.8 GHz/40 GHz

R&S®SMAB-B36S

Order Number 1420.9190.02

Descrizione

Super ultra high output power 31.8 GHz/40 GHz

R&S®SMAB-B37

Order Number 1420.7700.02

Descrizione

High output power 50 GHz

R&S®SMAB-K38

Order Number 1420.9255.02

Descrizione

Ultra high output power 50 GHz

R&S®SMAB-B39

Order Number 1420.7900.02

Descrizione

High output power 67 GHz

R&S®SMAB-K40

Order Number 1420.9278.02

Descrizione

Ultra high output power 67 GHz

Analog modulation options
Product
Descrizione
R&S®SMAB-K22

Order Number 1420.9710.02

Descrizione

High Performance Pulse Modulator

R&S®SMAB-K23

Order Number 1420.9726.02

Descrizione

Pulse Generator

R&S®SMAB-K24

Order Number 1420.9732.02

Descrizione

Multifunction Generator

R&S®SMAB-K25

Order Number 1420.9855.02

Descrizione

VOR/ILS

R&S®SMAB-K27

Order Number 1420.9749.02

Descrizione

Pulse Train

R&S®SMAB-K720

Order Number 1420.9790.02

Descrizione

AM/FM/φM

R&S®SMAB-K721

Order Number 1420.9784.02

Descrizione

Scan AM

R&S®SMAB-K724

Order Number 1420.9832.02

Descrizione

High dynamic uninterrupted level sweep

R&S®SMAB-K725

Order Number 1420.9861.02

Descrizione

Chirp signal generation

R&S®SMAB-B28

Order Number 1420.6579.02

Descrizione

Ramp sweep

Other options
Product
Descrizione
R&S®SMAB-B80

Order Number 1420.6504.02

Descrizione

Rear panel connectors (3 GHz/6 GHz)

R&S®SMAB-B81

Order Number 1420.6510.02

Descrizione

Rear panel connectors (12.75 GHz/20 GHz/31.8 GHz/ 40 GHz)

R&S®SMAB-B82

Order Number 1420.6527.02

Descrizione

Rear panel connectors (50 GHz/67 GHz) PC 1.85 mm

Extras
Product
Descrizione
R&S®ZZA-KNP21

Order Number 1177.8803.00

Descrizione

19’’ rack adapter for devices with 2 height units

R&S®ZZA-KNP31

Order Number 1177.8810.00

Descrizione

19" rack adapter for 3 HU model

R&S®TS-USB1

Order Number 6124.2531.00

Descrizione

USB serial adapter for RS-232 remote control

R&S®SMAB-Z10

Order Number 1420.6662.02

Descrizione

Spare SD card

R&S®SMAB-B85

Order Number 1420.6556.02

Descrizione

Removable mass storage

R&S®SMAB-B86

Order Number 1420.6562.02

Descrizione

Remote control GPIB and USB

R&S®SMAB-K28

Order Number 1420.9755.02

Descrizione

Power analysis

R&S®SMAB-K980

Order Number 1420.9284.02

Descrizione

Health and utilization monitoring service (HUMS)

Documentation
Product
Descrizione
R&S®DCV-2

Order Number 0240.2193.18

Descrizione

Documentation of Calibration Values

R&S®ACASMA100B

Order Number 3598.3307.03

Descrizione

R&S®DCV-2 0240.2193.18 R&S®SMA100B accredited calibration; up to 6 GHz

R&S®ACASMA100B

Order Number 3598.3236.03

Descrizione

R&S®SMA100B accredited calibration; 12.75 GHz to 40 GHz

R&S®ACASMA100B

Order Number 3598.3207.03

Descrizione

R&S®SMA100B accredited calibration; 50 GHz to 67 GHz

Base unit options
Product
Descrizione
R&S®SMAB-B92

Order Number 1420.8288.04

Descrizione

Platform height option: 2 HU with 5" touch display

R&S®SMAB-B93

Order Number 1420.8388.04

Descrizione

Platform height option: 3 HU with 7" touch display

Base unit options
Product
Descrizione
R&S®SMAB-K554

Order Number 1420.9884.02

Descrizione

Multiplier Control

Related videos

Simulazione dell’angolo di arrivo per ricevitori multicanale

Questo video mostra come definire uno scenario di radiogoniometria nel software R&S®Pulse Sequencer e come riprodurre lo scenario su una configurazione di misura a 4 canali del generatore R&S®SMW200A che è stata allineata in termini di ampiezza, ritardo e fase.

dic 09, 2020

R&S®SMW200A - Allineamento delle porte RF - Guida rapida

Questo video mostra come impostare i generatori di segnali vettoriali R&S®SMW200A e utilizzare l’opzione Allineamento delle porte RF SMW-K545 insieme al software RFPAL PC per generare segnali multipli che sono allineati in ampiezza, ritardo e fase all’ingresso di un dispositivo in prova multiporta.

dic 09, 2020

R&S®SMA100B – Scansione di livello ininterrotta ad alta dinamica

Questo video mostra come sfruttare la funzionalità di scansione di livello ininterrotta ad alta dinamica del generatore Rohde & Schwarz ® SMA100B per ricavare le curve di trasferimento del guadagno degli amplificatori.

set 16, 2019

R&S®SMA100B - Segnali con rumore di fase minimo

Ingegneria dei radar, caratterizzazione dei convertitore dati, test dell'immunità agli interferenti di una stazione base - tutti queste applicazioni richiedono segnali con rumore di fase minimo alle frequenze di offset rilevanti.

set 16, 2019

R&S®SMA100B – Misura della distorsione armonica di amplificatori ad alta potenza

Questo video mostra come il generatore R&S®SMA100B possa fornire contemporaneamente segnali di potenza d’uscita ultraelevata con le più basse armoniche.

set 16, 2019

R&S®SMA100B - Video del prodotto

Il video di illustra le caratteristiche del generatore di segnali a radiofrequenza e microonde R&S®SMA100B e le sue eccellenti prestazioni senza compromessi.

lug 23, 2019

Il segnale che fa la differenza

Questo video mostra la presentazione online del generatore SMA100B.

feb 12, 2019

Generazione innovativa di segnali analogici impulsivi

Questo video illustra come sia facile creare impulsi di breve durata utilizzando il generatore di segnali R&S®SMA100B.

feb 12, 2019

Richiedi informazioni

Hai qualche domanda o ti servono altre informazioni? Compila il modulo e ti ricontatteremo al più presto.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.