Test and debug more quickly with the industries fastest update rate Benefits from the RTP oscillscopes, offering the fastest update rate of maximum 750,000 waveforms/s. Benefits from the RTP oscillscopes, offering the fastest update rate of maximum 750,000 waveforms/s.
Cuando utilizo la función zoom para ver el límite ascendente de una señal rectangular, observo oscilación transitoria la cual no es real, ver captura de pantalla. ¿Cuál es el motivo?
Learn to use it most easily. 6 12 RTP, oscilloscope, scope, MSO, automated measurements, measurements, time, voltage, jitter, eye RTP - see the difference. Learn how to perform faster and more in-depth measurements on analog, RF or digital signals.
Learn about the powerful capabilities of the RTP oscilloscope to making sure that your design passes EMI test.
PAM-N Analysis with the R&S RTP Oscilloscope (Part 1) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes. Start with the Signal Configurator.
Manual de usuario de Rohde & Schwarz para ensayos de conformidad con DDR3. Describe los procedimientos de prueba.
La secuencia SCPI para configuración y consulta de datos para la interfaz I/Q digital opción K11.
Cuando se conecta un monitor adicional mediante la interfaz HDMI, se pierde la funcionalidad táctil. ¿Cómo puedo hacer para que la funcionalidad táctil esté disponible otra vez?
The Zoom function does not show any waveform data at specific settings, especially at slower timebases in combination with higher sample rates, High resolution and roll mode with more channels. The problem is gone if a lower sample rate is chosen.
Embedding & Equalization with the R&S RTP Oscilloscope (Part 1) Learn about key advantages of the Embedding and Equalization option of the R&S RTP & RTO6 oscilloscopes. Start with the Signal Configurator.
Manual de usuario de Rohde & Schwarz para ensayos de conformidad con D-PHY. Describe los procedimientos de prueba.
Falla la conexión de R&S®ScopeSuite con RTO/RTP
RTP Oscilloscopes with External Frontends (Part 2 ) The R&S RTP oscilloscope offers a comprehensive set of tools for analysing widebad RF signals together with the external frontends downconverted. Start with powerful trigger events, responsive spectrum analysis or the unique IQ mode to prepare in depth signal analysis.
RTP oscilloscope.
Manual de Rohde & Schwarz para la opción de automatización de ScopeSuite. Describe los procedimientos de prueba.
This example demonstrates the power of Advanced Eye analysis with the RTP oscilloscope on an Automotive Ethernet PAM4 signal at 5 Gbaud. PAM-N Analysis with the R&S RTP Oscilloscope (Part 3) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes together with the Advanced Eye option to characterize and verify signal transitions.
PAM-N Analysis with the R&S RTP Oscilloscope (Part 2) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes. In combination with the CDR option, obtain the fastest eye diagrams to characterize signal behaviour in seconds.
The RTP oscilloscope extends traditional de-embedding capabilities with flexible filter structures directly in the acquisition path. This allows waveform correction in real time. For the first time, users can trigger on corrected waveforms and focus on debugging the true device characteristics. 9 12 RTP, oscilloscope, scope, MSO, user interface, tool bar, toolbar RTP- see the difference.
The RTP addresses this with an hardware-based math approach in the acquisition path, enabling for the first time triggering on math signals. 10 12 RTP, oscilloscope, scope, MSO, differential, differential signal, common mode, trigger RTP- see the difference. Benefit from differential signal and common mode beeing calculated in real-time.
Nov 12, 2020
R&S RTP oscilloscope from Rohde & Schwarz wins prestigious LEAP AwardThe R&S RTP high-performance oscilloscope was granted this year’s LEAP Award (Leadership in Engineering Achievement Program) in silver in the test and measurement category. The award is given annually to most innovative and forward-thinking products serving the design engineering space, and was selected by 14 judges from various engineering and ICT institutions.
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
Osciloscopio, osciloscopio de alto rendimiento RTP, radar para el sector automotriz, análisis de pulsos Aprenda más sobre la configuración básica con un osciloscopio de alto rendimiento RTP.
Manual de Rohde & Schwarz para ensayos de conformidad con eMMC. Describe los procedimientos de prueba.
RTP oscilloscopes can trigger on signals as small as 1/1000th of a vertical division thanks to digital triggering and adjustable hysteresis. 3 12 RTP, oscilloscope, scope, MSO, update rate, trigger, digital trigger RTP- see the difference. Trigger with highest sensitivity at full bandwidth.
Mar 26, 2024
embedded world 2024: Rohde & Schwarz presents its cutting-edge test solutions for embedded systemsRohde & Schwarz offers comprehensive test and measurement solutions for embedded design challenges for today’s requirements for efficiency, safety, reliability and interoperability. The highlights will be showcased at the embedded world Exhibition & Conference 2024 in Nuremberg, Germany.
Sep 17, 2020
Rohde & Schwarz offers bandwidth upgrades for selected oscilloscopes at no extra chargeBandwidth is the most important aspect of an oscilloscope. To support design engineers in current and future design challenges, Rohde & Schwarz is introducing an attractive promotion for selected oscilloscope models: when purchasing an R&S RTO2000 or R&S RTP, now customers can upgrade the bandwidth with no extra costs.
Esta opción adicional convierte los osciloscopios R&S RTO y RTP en potentes herramientas de depuración multifuncionales. Video, TDR/TDT, osciloscopios, RTO, RTP Evalúe la pérdida de impedancia y transmisión de sus trazas de señal con la opción de análisis TDR/TDT de los osciloscopios RTO o RTP.
Manual de usuario de Rohde & Schwarz para ensayos de conformidad con Ethernet. Describe los procedimientos de prueba.
Embedding & Equalization with the R&S RTP Oscilloscope (Part 2) Learn about how to configure cable emulation within the Embedding setup dialog
Embedding & Equalization with the R&S RTP Oscilloscope (Part 3) The Eye Diagram is an effective tool to validate signal integrity. This video compares the eye diagram on a signal acquired at the output of a USB transmitter versus a waveform with some added cable emulation.