UART/RS232 oscilloscope software

Triggering and decoding

UART/RS232 oscilloscope software
Abrir Lightbox
UART/RS232 oscilloscope software
Abrir Lightbox
UART/RS232 oscilloscope software
Abrir Lightbox
UART/RS232 oscilloscope software
Abrir Lightbox
UART/RS232 oscilloscope software
Abrir Lightbox
UART/RS232 oscilloscope software
Abrir Lightbox
UART/RS232 oscilloscope software
Abrir Lightbox
UART/RS232 oscilloscope software
Abrir Lightbox
UART/RS232 oscilloscope software
Abrir Lightbox
UART/RS232 oscilloscope software
Abrir Lightbox
UART/RS232 oscilloscope software, Software UART/RS232 oscilloscope software, Screenshot UART/RS232 oscilloscope software, Screenshot UART/RS232 oscilloscope software, Screenshot UART/RS232 oscilloscope software, Screenshot UART/RS232 oscilloscope software, Screenshot UART/RS232 oscilloscope software, Screenshot UART/RS232 oscilloscope software, Screenshot UART/RS232 oscilloscope software, Screenshot UART/RS232 oscilloscope software, Screenshot

Key Facts

  • Trigger on start, break, data and various error conditions
  • Telegram display as color-coded bus signals and in decode table
  • Supports decoding of up to 4 serial buses from analog or digital channel signals
  • On-screen serial decoding is time-correlated with the serial data waveform
  • Fastest UART and RS-232/RS-422/RS-485 eye-diagram mask testing with standard mask test functionality
  • Multi-domain icon

Oscilloscope software

All Rohde & Schwarz oscilloscopes support triggering and decoding of UART and of RS-232, RS-422 and RS-485 buses. You can set up decoding in seconds. For detailed analysis, results can be viewed as color-coded telegrams and/or in a table. Errors are identified efficently and reliably using the hardware-accelerated trigger. You can trigger on start, break, data and various error conditions.

Features & benefits

Fast bus setup

Bus setup in seconds with the app cockpit

Starting from the app cockpit, it only takes a few steps to configure any given protocol. Once the bus to decode has been chosen, the connected channels selected and the correct levels set, decoding begins automatically.

Abrir Lightbox

Bus decoding selection with the app cockpit.

Color-coded telegram display

Telegram display as color-coded bus signals and in decode table

You can analyze the decoded bus frames by overlaying the signal with color-coded data. Address and data content can be displayed in hex, bin or ASCII format. You always have the best overview with the flexible screen setup. The telegrams can also be displayed in a concise table.

Abrir Lightbox

Decoded frames are color-coded.

Strong trigger capability

Strong trigger capability on start, break, data and various error conditions

The protocol-specific trigger lets you reliably isolate protocol events and errors. Thanks to high acquisition rates, Rohde & Schwarz oscilloscopes are ideal for finding errors quickly, allowing decoding of protocol-specific trigger results. The hardware-based triggering is available on specific protocol content, e.g. addresses, data and protocol errors.

Abrir Lightbox

Protocol trigger setup dialog.

Available models

Available models
Modelos
Serial standard
Decode table
Trigger
Label support
Search
Base unit

R&S®RTP-K2

Order Number 1337.8610.02

Click on order no. to copy
Order Number 1337.8610.02 is now copied to your clipboard.
Serial standard
UART/ RS-232/ RS-422/ RS-485
Decode table
Trigger
Label support
Search
Base unit

R&S®RTO-K2

Order Number 1329.7277.02

Click on order no. to copy
Order Number 1329.7277.02 is now copied to your clipboard.
Serial standard
UART/ RS-232/ RS-422/ RS-485
Decode table
Trigger
Label support
Search
Base unit

R&S®RTA-K2

Order Number 1335.7698.02

Click on order no. to copy
Order Number 1335.7698.02 is now copied to your clipboard.
Serial standard
UART/ RS-232/ RS-422/ RS-485
Decode table
Trigger
Label support
Search
Base unit

R&S®RTM-K2

Order Number 1335.8813.02

Click on order no. to copy
Order Number 1335.8813.02 is now copied to your clipboard.
Serial standard
UART/ RS-232/ RS-422/ RS-485
Decode table
Trigger
Label support
Search
Base unit

R&S®RTB-K2

Order Number 1333.1028.02

Click on order no. to copy
Order Number 1333.1028.02 is now copied to your clipboard.
Serial standard
UART/ RS-232/ RS-422/ RS-485
Decode table
Trigger
Label support
Search
Base unit

R&S®RTC-K2

Order Number 1335.7246.03

Click on order no. to copy
Order Number 1335.7246.03 is now copied to your clipboard.
Serial standard
UART/ RS-232/ RS-422/ RS-485
Decode table
Trigger
Label support
Search
Base unit

R&S®RTH-K2

Order Number 1325.9975.02

Click on order no. to copy
Order Number 1325.9975.02 is now copied to your clipboard.
Serial standard
UART/ RS-232/ RS-422/ RS-485
Decode table
Trigger
Label support
Search
Base unit

Más información

Decoding over a minute of bus data using deep memory
Decodificación de datos de bus con una duración superior a un minuto usando la memoria profunda

Descubra cómo los osciloscopios Rohde & Schwarz con memoria profunda pueden grabar más de un minuto de datos de bus CAN, tal como se muestra en un R & S®RTO.

Más información

Solicitar información

¿Tiene preguntas o necesita información adicional? Simplemente complete este formulario y nos pondremos en contacto con usted.

Permiso de marketing

Se ha enviado su solicitud. Nos pondremos en contacto con usted lo antes posible.
An error is occurred, please try it again later.