Key Facts
- Frequency range upgradeable to 10 MHz
- Basic accuracy of ±0.05 % for impedance measurements
- Basic accuracy of ±0.03° for phase measurements
- DC bias up to 40 V
- Data logging function
Key Facts
The R&S®LCX LCR meters are versatile, extremely accurate and perform measurements quickly. They are ideal for challenging applications in research, development and production. Two instrument models and various options cover applications with a test signal frequency of up to 10 MHz. Internal and external bias functions, comprehensive analysis options and versatile test fixtures expand the wide range of possible applications.
Both R&S®LCX models combine high measurement speed, accuracy and versatile measurement capabilities. This makes them ideal for standard measurements in development, for material analysis in research as well as for fast production testing. With their broad measurement ranges, they also cover applications with extremely low and extremely high impedances. Three measurement times are available:
All R&S®LCX models measure under DC conditions. The AC range already begins at 4 Hz. The upper frequency limit on the R&S®LCX100 is 300 kHz. In its base configuration, the R&S®LCX200 is designed for a maximum frequency of 500 kHz; this frequency limit can, however, be extended to 1 MHz or 10 MHz. This means that the ideal instrument is available for any given application and budget.
Test signals can be generated from 100 mV to 10 V and deliver a current of up to 200 mA. The instruments have a selectable output impedance of 100 Ω or 10 Ω. The actual current flow and the voltage applied are measured using the monitor function.
In many applications, an adjustable DC bias is needed to measure C and L components at different operating points. The R&S®LCX100 and R&S®LCX200 generate a DC bias voltage of up to 10 V. As an option, it is also possible to set a DC bias current (up to 200 mA). DC bias voltages of up to 40 V can be applied at an external connection on the rear panel (R&S®LCX-K108 option) using a standard DC power supply, for example an R&S®NGA.
The R&S®LCX LCR meters provide a fast logging function for recording all measured values. The data can be saved on an external USB flash drive or transferred to an external PC via USB or LAN. With a data rate of up to 10 sample/s, the measured values are available every 100 ms.
Order Number 5601.6000.02
IEEE-488 (GPIB) interface
Order Number 3630.1922.03
Advanced analysis functions
Order Number 3660.7741.03
Digital I/O ports and binning function
Order Number 3692.9791.03
Extended bias functions
Order Number 3630.1880.03
Frequency upgrade to 1 MHz, for R&S®LCX200
Order Number 3630.1900.03
Frequency upgrade to 10 MHz, for R&S®LCX200
Order Number 3639.2296.02
Test fixture for axial/radial lead type devices
Order Number 3638.6446.02
Kelvin clip lead
Order Number 3639.2509.02
Test fixture for SMD components
Order Number 3639.2515.02
Test tweezers for SMD components
Order Number 3639.2521.02
Transformer test cables
Order Number 3639.2538.02
BNC extension, length: 1 m
Order Number 5601.4059.02
19" rack adapter, 2 HU
Transformers are passive devices that are primarily used to convert or "transform" alternating current (AC) from one voltage level to another. One very common application of transformers is in AC to DC power supplies, in which mains voltage is stepped down before being rectified and filtered to produce DC. There are numerous other applications for transformers, such as providing electrical isolation or for impedance matching.
Read this educational note and dive into the discussion about the six most important transformer measurements: turns ratio, mutual inductance, phase angle, primary and secondary inductance, leakage inductance, and interwinding capacitance.
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz
1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).
2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.
3. A participação é gratuita e não depende da compra de mercadorias ou serviços.
4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.
5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:
Prêmio: 1 osciloscópio digital R&S®RTB2000
6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.
7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.
8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.
9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.
10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.
11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.
12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.
13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.