Key Facts

  • Frequency range upgradeable to 10 MHz
  • Basic accuracy of ±0.05 % for impedance measurements
  • Basic accuracy of ±0.03° for phase measurements
  • DC bias up to 40 V
  • Data logging function

The top-class in component testing

The R&S®LCX LCR meters are versatile, extremely accurate and perform measurements quickly. They are ideal for challenging applications in research, development and production. Two instrument models and various options cover applications with a test signal frequency of up to 10 MHz. Internal and external bias functions, comprehensive analysis options and versatile test fixtures expand the wide range of possible applications.  

Features & benefits

Fast, accurate and versatile

Both R&S®LCX models combine high measurement speed, accuracy and versatile measurement capabilities. This makes them ideal for standard measurements in development, for material analysis in research as well as for fast production testing. With their broad measurement ranges, they also cover applications with extremely low and extremely high impedances. Three measurement times are available:

  • Fast: ≤ 15 ms
  • Medium: ≤ 100 ms
  • Slow: ≤ 500 ms
The basic accuracy for impedance measurements is ±0.05 %, and for phase measurements ±0.03°.  

Selectable frequency range

All R&S®LCX models measure under DC conditions. The AC range already begins at 4 Hz. The upper frequency limit on the R&S®LCX100 is 300 kHz. In its base configuration, the R&S®LCX200 is designed for a maximum frequency of 500 kHz; this frequency limit can, however, be extended to 1 MHz or 10 MHz. This means that the ideal instrument is available for any given application and budget.  

Test signals for all requirements

Test signals can be generated from 100 mV to 10 V and deliver a current of up to 200 mA. The instruments have a selectable output impedance of 100 Ω or 10 Ω. The actual current flow and the voltage applied are measured using the monitor function.  

DC bias

In many applications, an adjustable DC bias is needed to measure C and L components at different operating points. The R&S®LCX100 and R&S®LCX200 generate a DC bias voltage of up to 10 V. As an option, it is also possible to set a DC bias current (up to 200 mA). DC bias voltages of up to 40 V can be applied at an external connection on the rear panel (R&S®LCX-K108 option) using a standard DC power supply, for example an R&S®NGA.  

Data logging function

The R&S®LCX LCR meters provide a fast logging function for recording all measured values. The data can be saved on an external USB flash drive or transferred to an external PC via USB or LAN. With a data rate of up to 10 sample/s, the measured values are available every 100 ms.  

Available models

Available models
Modelos
Measurement functions
Frequency range
Test signal voltage (RMS)
Test signal current
Internal bias voltage
Começando em

R&S®LCX100

Order Number 3629.8856.02

Measurement functions
Cp, Cs, Lp, Ls, D, Q, G, Rp, Rs, Rdc, R, X, Z, Y, Θd, Θr, B, M, N
Frequency range
DC, 4 Hz to 300 kHz
Test signal voltage (RMS)
10 mV to 10 V 
Test signal current
1 mA to 200 mA
Internal bias voltage
0 V - 10 V
Começando em
Consultar preço

R&S®LCX200

Order Number 3629.8856.03

Measurement functions
Cp, Cs, Lp, Ls, D, Q, G, Rp, Rs, Rdc, R, X, Z, Y, Θd, Θr, B, M, N
Frequency range
DC, 4 Hz to 500 kHz (1 MHz or 10 MHz optional)
Test signal voltage (RMS)
≤ 1 MHz: 10 mV to 10 V,
≤ 5 MHz: 50 mV to 2 V,
> 5 MHz: 100 mV to 1 V
Test signal current
≤ 1 MHz: 1 mA to 100 mA,
> 1 MHz to ≤ 5 MHz: 1 mA to 20 mA,
> 5 MHz: 1 mA to 10 mA
Internal bias voltage
0 V - 10 V
Começando em
Consultar preço

Available options

Hardware options
Product
Descrição
R&S®NG-B105

Order Number 5601.6000.02

Descrição

IEEE-488 (GPIB) interface

Software options
Product
Descrição
R&S®LCX-K106

Order Number 3630.1922.03

Descrição

Advanced analysis functions

R&S®LCX-K107

Order Number 3660.7741.03

Descrição

Digital I/O ports and binning function

R&S®LCX-K108

Order Number 3692.9791.03

Descrição

Extended bias functions

R&S®LCX-K201

Order Number 3630.1880.03

Descrição

Frequency upgrade to 1 MHz, for R&S®LCX200

R&S®LCX-K210

Order Number 3630.1900.03

Descrição

Frequency upgrade to 10 MHz, for R&S®LCX200

Accessories
Product
Descrição
R&S®LCX-Z1

Order Number 3639.2296.02

Descrição

Test fixture for axial/radial lead type devices

R&S®LCX-Z2

Order Number 3638.6446.02

Descrição

Kelvin clip lead

R&S®LCX-Z3

Order Number 3639.2509.02

Descrição

Test fixture for SMD components

R&S®LCX-Z4

Order Number 3639.2515.02

Descrição

Test tweezers for SMD components

R&S®LCX-Z5

Order Number 3639.2521.02

Descrição

Transformer test cables

R&S®LCX-Z11

Order Number 3639.2538.02

Descrição

BNC extension, length: 1 m

R&S®ZZA-GE23

Order Number 5601.4059.02

Descrição

19" rack adapter, 2 HU

Educational note: Understanding transformer testing

Educational note: Understanding transformer testing

Transformers are passive devices that are primarily used to convert or "transform" alternating current (AC) from one voltage level to another. One very common application of transformers is in AC to DC power supplies, in which mains voltage is stepped down before being rectified and filtered to produce DC. There are numerous other applications for transformers, such as providing electrical isolation or for impedance matching.

Read this educational note and dive into the discussion about the six most important transformer measurements: turns ratio, mutual inductance, phase angle, primary and secondary inductance, leakage inductance, and interwinding capacitance.

Related videos

Webpage, VNC & FTP on R&S®DC Power Supplies

Learn how easy it is to control and operate our instrument from any location via ethernet-based remote services

Impedance Measurements using R&S®LCX200 & MFIA

The LCR Meters and Impedance Analyzers from Rohde & Schwarz are ideal for measuring impedance at a fixed frequency as well as for determining the best operating point for the component under test

R&S®LCX Test Fixtures

The R&S®LCX Z1/Z2/Z3/Z4/Z5 test fixtures from Rohde & Schwarz can perform measurements on a wide range of components.

Transformer Testing With R&S®LCX200 and R&S®LCX-Z5

The R&S®LCX-Z5 test fixture is designed for measuring transformers in combination with the measurement functions of the R&S®LCX LCR meters.

R&S®LCX-K106: ferramenta de verificação da função de análise avançada

A ferramenta de verificação para os medidores LCR R&S®LCX permite medições de impedância dinâmicas através da varredura da frequência do sinal de teste, do nível e da polarização de CC.

Principais características do R&S®LCX100 e do R&S®LCX200

Os medidores LCR R&S®LCX vêm com uma tela sensível ao toque de alta resolução, uma frequência máxima de até 10 MHz, funções de medição versáteis e recursos de registro

R&S®LCX-K108: funções de polarização ampliadas

A opção R&S®LCX-K108 permite que o usuário aplique uma polarização de tensão CC externa de até 10 V e uma polarização de corrente CC interna de até 200 mA ao dispositivo em teste.

Peça informações

Você tem alguma pergunta ou precisa de informação adicional? Simplesmente preencha este formulário e nós respondemos imediatamente.

Licença de marketing

O seu pedido foi submetido. Iremos contactá-lo em breve.
An error is occurred, please try it again later.
Informações gerais e legais

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz

1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).

2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.

3. A participação é gratuita e não depende da compra de mercadorias ou serviços.

4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.

5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:

Prêmio: 1 osciloscópio digital R&S®RTB2000

6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.

7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.

8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.

9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.

10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.

11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.

12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.

13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.