R&S®ENV216 two-line V-network

For disturbance voltage measurements on single-phase EUT

R&S®ENV216 two-line V-network
Abrir Lightbox
R&S®ENV216 two-line V-network
Abrir Lightbox
R&S®ENV216 two-line V-network
Abrir Lightbox
R&S®ENV216 two-line V-network
Abrir Lightbox
R&S®ENV216 two-line V-network
Abrir Lightbox
R&S®ENV216 two-line V-network
Abrir Lightbox
R&S®ENV216 two-line V-network, Front view R&S®ENV216 two-line V-network, Front High R&S®ENV216 two-line V-network, Side view R&S®ENV216 two-line V-network, Back view R&S®ENV216 two-line V-network, Back view R&S®ENV216 two-line V-network, Hero view

Key Facts

  • Frequency range 9 kHz to 30 MHz
  • Power handling capacity up to 16 A (country-specific)
  • Simulated impedance (50 μH + 5 Ω) || 50 Ω in line with CISPR 16-1-2
  • V-network in line with CISPR, EN, VDE, ANSI, FCC Part 15 and MIL-STD-461
  • Calibrated in line with CISPR 16-1-2

For disturbance voltage measurements on single-phase EUTs

The R&S ENV216 two-line V-network meets the requirements of CISPR 16-1-2 and EN 55016-1-2 for V-networks with a simulated impedance of (50 μH + 5 Ω) || 50 Ω in the frequency range from 9 kHz to 30 MHz as well as the ANSI C63.4 in the frequency range from 150 kHz to 30 MHz. A socket with protective earth contacts connects to the EUT. Various models with country-specific connector systems are available. The compact design and low weight make the R&S®ENV216 ideal for frequently varying applications, especially for on-site disturbance voltage measurements on single-phase EUT.

Features & benefits

Air-core inductance and artificial hand

Air-core design and artificial hand

The R&S®ENV216 two-line V-network is based on air-core inductances and contains a artificial hand  to mimic the influence of the user’s hand while measuring  disturbance voltage.

Highpass filter

Switch-selectable 150 kHz highpass filter 

 A 150 kHz highpass filter can be inserted to prevent the measuring receiver from being overloaded by high levels of low frequency spectra.

Attenuator

Built-in 10 dB attenuator pad

The R&S®ENV216 two-line V-network is equipped with a 10 dB attenuator pad to ensure standard impedance irrespective of the measuring receiver's input attenuation. 

Pulse limiter

Built-in pulse limiter (can be switched off)

A built-in pulse limiter that can be switched off protects the measuring receiver's input from high energy radio frequency interference pulses.

Remote control

Remote control with TTL levels (compatible with R&S measuring receivers)

TTL control inputs that can be driven by controllers or Rohde & Schwarz measuring receivers are provided for remote control of phase selection and highpass filter activation in an automatic test system. Optocouplers prevent pick-up of external disturbances.

Available models

Available models
Modelos
Max. continuous current
Country-specific connector

R&S®ENV216

Order Number 3560.6550.12

Max. continuous current
16 A
Country-specific connector
Germany, Austria, Finland, the Netherlands, Norway, Russia, Sweden, Korea; occasionally: Portugal, Spain

R&S®ENV216

Order Number 3560.6550.13

Max. continuous current
13 A
Country-specific connector
UK, Ireland, Hong Kong, Malaysia, Singapore

R&S®ENV216

Order Number 3560.6550.14

Max. continuous current
16 A
Country-specific connector
France, Belgium and Czech Republic

R&S®ENV216

Order Number 3560.6550.15

Max. continuous current
10 A
Country-specific connector
China, Australia, New Zealand

R&S®ENV216

Order Number 3560.6550.16

Max. continuous current
15 A
Country-specific connector
USA, Canada, Japan, Taiwan, Mexico, Central America

Available options

General
Product
Descripción
R&S®EZ-21

Order Number 1107.2087.03

Descripción

Control Cable, 3 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200

R&S®EZ-21

Order Number 1107.2087.10

Descripción

Control Cable, 10 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200 

R&S®EZ-29

Order Number 1326.6470.03

Descripción

Control Cable, 3 m

ESW, ESR, ESRP, ESL, FSW/FSVx to ENVxxx

R&S®EZ-29

Order Number 1326.6470.10

Descripción

Control Cable, 10 m

ESW, ESR, ESRP, ESL, FSW/FSVx to ENVxxx

Solicitar información

¿Tiene preguntas o necesita información adicional? Simplemente complete este formulario y nos pondremos en contacto con usted.

Permiso de marketing

Se ha enviado su solicitud. Nos pondremos en contacto con usted lo antes posible.
An error is occurred, please try it again later.
Información general y jurídica

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Términos y condiciones del sorteo de premios con motivo del 10° aniversario de los osciloscopios de Rohde & Schwarz

1. El sorteo «10 años de osciloscopios de Rohde & Schwarz» (en adelante el «sorteo») está organizado por Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Múnich, Alemania, tel. +49 89 41 29 0 (en adelante «R&S»).

2. Todos los participantes pueden inscribirse en el sorteo entre el 1 de enero de 2020 y el 31 de diciembre de 2020 indicando su nombre, el nombre de su compañía y la dirección de correo electrónico empresarial.

3. La participación es gratuita y no está vinculada a la compra de bienes o servicios.

4. El sorteo está destinado únicamente a personas jurídicas, y solamente las personas jurídicas tienen facultad para recibir los premios. No está permitida la participación de una persona individual en su propio nombre y cuenta, sino que deberá hacerlo como representante de una persona jurídica rellenando el formulario de participación en nombre y por cuenta de dicha persona jurídica.

5. Los participantes pueden ganar uno de los 10 R&S®RTB2000 sorteados en el periodo entre el 1 de enero de 2020 y el 31 de diciembre de 2020:

Premio: 1 osciloscopio digital R&S®RTB2000

6. El sorteo se celebra en la sede central de R&S, Muehldorstrasse 15, 81671 Múnich (Alemania). Los ganadores de los premios serán informados por correo electrónico en un plazo de cinco (5) días laborables.

7. El representante autorizado de la persona jurídica deberá notificar a R&S que acepta el premio. En caso de denegar la aceptación o de no obtenerse respuesta en un plazo de dos (2) semanas, se sorteará un nuevo ganador. Si no puede determinarse un ganador en un espacio de cuatro (4) semanas, el sorteo se dará por finalizado y el premio se dará por perdido.

8. Los empleados de R&S, sus familiares, así como cualquier persona que esté implicada en el proceso del sorteo y sus familiares quedan excluidos de rellenar el formulario de participación.

9. No está permitido abonar el equivalente en metálico ni intercambiar los premios. Los premios son intransferibles. Todos los impuestos, gravámenes, tasas de aduana, cuotas y otros pagos exigidos en el país del participante correrán a cargo del participante.

10. Los datos personales se procesarán exclusivamente para los fines de este sorteo de premios y se eliminarán cuatro (4) semanas después de finalizar el mismo, salvo otro acuerdo.

11. R&S se reserva el derecho de descalificar del concurso a cualquier participante que no cumpla los presentes términos y condiciones. En estos casos, los premios también podrán retirarse con efecto retroactivo. En caso de retirarse un premio con efecto retroactivo como consecuencia del incumplimiento de los presentes términos y condiciones, el respectivo participante deberá devolverlo, corriendo con los gastos correspondientes, a la dirección de R&S indicada en el punto 1, y se sorteará un nuevo ganador.

12. Los participantes no tienen derecho a reclamar los premios de este sorteo, ni está previsto ningún recurso legal a este respecto.

13. El sorteo, y cualquier relación contractual que se derive del mismo entre R&S y el respectivo participante, se regirán e interpretarán según la legislación de Alemania, excluyendo todo recurso por conflictos de leyes. Los tribunales de Múnich, Alemania, tendrán la competencia exclusiva en caso de cualquier litigio relacionado directa o indirectamente con la participación en este concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.